DC Sputtering Source Reference and Guide

DC Sputtering Power Supply (100 W): Requirements, Constraints and Build Plan

Status: draft v0.1, 2026-11-13. Owner: Alacrity R&D. Partner: Hacker Fab (Waterloo / CMU).

Scope: a 100 W DC magnetron sputtering supply for the Hacker Fab DC sputtering machine, powered only from a Mean Well UHP-200-24.

Warning: the output of this supply is lethal (up to 1.5 kV open circuit, up to 0.4 A in operation). This page is an engineering specification, not a safety approval. Nothing here replaces a review by a qualified person before first power-up.

How to read this page

1. Starting point

1.1 The Waterloo machine today H1

1.2 Why an electrophoresis supply fails on a plasma

Electrophoresis supplies are sold with no-load detection, sudden-load-change detection, ground-leak detection and arc detection as safety features E9. Each one is triggered by normal plasma behaviour.

Protection in the electrophoresis supply Why a sputtering plasma trips it What this supply does instead
No-load detection Before ignition the chamber is an open circuit P1 Holds the strike voltage into an open circuit, with only a configurable ignition timeout (IGN-2)
Sudden load change detection Ignition takes the load from open circuit to a few kOhms in ms, an arc takes it to near short circuit P8 Current-source output, soft strike, controlled ramp (IGN-1, IGN-4, IGN-5)
Ground-leak detection The anode is the earthed chamber, so the return current flows in earthed metal by design P1 Positive output bonded to protective earth inside the supply. Safety comes from enclosure, interlocks and earthing (OUT-1, SAF-7, SAF-8)
Arc detection with latched shutdown Micro-arcs are a normal part of sputtering, above all on new or oxidised targets P8 Quench in microseconds, wait, recover automatically, count. Latch only on persistent arcing (ARC-1 to ARC-7)

2. The load: what the literature says the supply has to drive

2.1 Operating window

Quantity DC diode glow (no magnets) P1 DC magnetron, typical [P1]P3 Hacker Fab today H1 Commercial 1 to 1.3 inch sources [E6][E7]E8
Argon pressure 2 to 4 Pa (15 to 30 mTorr) 0.1 to 1.5 Pa (0.75 to 11 mTorr) 10 to 300 mTorr 0.5 to 600 mTorr (MAK 1.3), 2 to 50 mTorr (ONYX-1), about 1 mTorr to 1 Torr (MTI 1 inch)
Cathode voltage 2 to 5 kV 300 to 700 V not documented yet 200 to 1000 V (MAK, MTI), 100 to 1000 V (ONYX-1)
Current about 1 mA/cm² 4 to 60 mA/cm² not documented yet up to 1 A (ONYX-1), 2 A (MAK), 3 A (MTI)
Power not given several tens of W/cm² about 20 W, 2.8 W/cm² (derived) 75 W indirect cooled (ONYX-1), 250 W (MTI), 350 W (MAK), all water cooled
Magnetic field at target none about 20 to 50 mT not documented yet NdFeB magnets

Supplier guidance for target loading is about 16 W/cm² with indirect cooling and about 39 W/cm² with direct water cooling E7.

2.2 Electrical behaviour that shapes the design

2.3 What 100 W means on a 30 mm target (derived)

3. What professional supplies do

AE MDX 500 E2 AE MDX 1 kW / 1.5 kW E3 AE Pinnacle family E4 TRUMPF TruPlasma DC 3000 (G2) E5 This supply (target)
Rated power 500 W 1 kW / 1.5 kW 3 kW and up 10 to 300 kW 100 W
Run voltage 0 to 600 V at 1 A, or 0 to 1200 V at 0.5 A 1000 or 1300 V / 500 or 750 V 370 to 1000 V at full power (3000), 325 to 800 V loads (Plus+) 1000 V, full power over a 1:4 impedance range 250 to 800 V at full power, 1000 V max
Strike voltage 1200 V range 1500 V "soft" (standard Z), 800 V (low Z); 800 or 1200 V on the 1.5 kW programmable strike voltage limit n/s 600 to 1200 V programmable
Regulation power, current, voltage power, current, voltage power, current, voltage n/s power, current, voltage
Ripple 2% p-p at 100 kHz, 1% p-p line 5% at 50 kHz line-related below 2% RMS (Plus+), 5% RMS (3000) n/s 5% p-p
Accuracy display within 2% of reading or 0.2% of full scale regulation 0.2% repeatability 0.1% 0.5%, repeatability 0.2% (Series 4000) 2% of reading or 0.5% of full scale
Energy into an arc "orders of magnitude" below older designs, no figure low stored energy, no figure below 1 mJ per kW (series), below 6 mJ per kW (3000) below 0.3 mJ per kW 5 mJ absolute max, goal 1 mJ
Arc detection senses a change in current (Arc-Out) Arc-Out 0.5 to 3 µs (series), 3 µs (3000), below 25 µs (Plus+) below 100 ns, adjustable U and I thresholds 2 µs
Arc interruption n/s adjustable suppression time 10 µs (3000), below 200 µs (Plus+); trip level, delay and shutdown time programmable n/s converter off within 10 µs, off-time 0.1 to 100 ms
Ramp 0.1, 1 or 10 s 1 to 10 s or 1 to 10 min ramp and run recipes n/s 0.1 s to 10 min
Interlocks and remote 25-pin analog/digital port, 0 to 10 V, three interlock pins (vacuum, water, auxiliary) front panel and user port AE Bus serial, Profibus, DeviceNet option n/s hardware interlock loop, isolated serial
Output connection UHF (N or SHV optional), RG-8 coax UHF or terminal block n/s n/s SHV, RG-59 coax
Standards claimed EN 50081-2, EN 50082-2, EN 50178 n/s IEC 61010-1 and IEC 61326-1 (Pinnacle); EN 55011, EN 61000-6-2, EN 50178 (Plus+) n/s design targets IEC 61010-1, IEC 61326-1

n/s = not stated in the documents we checked.

Takeaways:

4. Requirements

4.1 Input and power budget (IN)

ID Requirement Level Basis
IN-1 Runs from one Mean Well UHP-200-24 (24 V, 8.4 A, 201.6 W). No other power input. MUST Project decision (availability) E1
IN-2 Full performance from 22.8 to 25.2 V (the UHP trim range). No damage from 0 to 32 V, which covers the UHP over-voltage window of 26.4 to 31.2 V. MUST E1
IN-3 Input current at most 6.0 A in every operating and fault condition, enforced in hardware. The UHP goes into hiccup at 110 to 140% of rated power and tolerates 150% for 100 ms only. MUST E1
IN-4 Efficiency at least 75% at 100 W, goal 85%. At 85% the supply draws 118 W, 4.9 A, 58% of the UHP rating (derived). SHOULD E1; Pinnacle 3000 is above 90% E4
IN-5 Waits for a stable 24 V (under-voltage lockout near 20 V with hysteresis), tolerates the UHP rise time of 80 ms and setup time of up to 3 s, and soft-starts so that inrush stays inside IN-3. MUST E1
IN-6 When the arc handler stops the converter, the 24 V bus overshoot stays below 26.4 V. The UHP over-voltage protection latches and needs a power cycle. MUST E1
IN-7 Fuse and reverse-polarity protection on the 24 V input. MUST Single-fault thinking of S1
IN-8 The UHP is mounted as its datasheet assumes (aluminium plate or chassis wall of about 300 x 300 x 3 mm, 5 cm free space), or derated. SHOULD E1

4.2 Output envelope (OUT)

ID Requirement Level Basis
OUT-1 Negative output to the cathode. Positive output bonded to chassis and protective earth. The anode is the earthed chamber. MUST P1; ground-fault lesson of H1
OUT-2 Regulated power 5 to 100 W continuous. Hard cap at 100 W in hardware and firmware. MUST Project decision; section 2.3
OUT-3 Full 100 W from 250 V to 800 V (625 Ω to 6.4 kΩ). MUST 300 to 700 V typical P1 plus margin for high-pressure operation H1 and for different targets P7. Commercial units give full power over a 1:2 to 1:3 voltage range [E4]E5
OUT-4 Run voltage limit 1000 V. Operation down to 150 V at reduced power. MUST Small sources are rated 100 or 200 to 1000 V [E6][E7]E8; MDX 500 ranges E2
OUT-5 Output current 0 to 400 mA, goal 500 mA. MUST / SHOULD 100 W at 250 V (derived); ONYX-1 0.1 to 1 A E7
OUT-6 Stable down to 10 mA for conditioning and very thin films. SHOULD Glow regime extends to low current P1
OUT-7 Voltage ripple at most 5% p-p at 100 W and 400 V or more into a resistive load. Current ripple into the plasma at most 10% p-p. MUST MDX 500 2% p-p, MDX 1 kW 5% [E2]E3; ripple is multiplied by n in the plasma (derived from P4)
OUT-8 Current-source output: high output impedance at the switching frequency. Total capacitance across the output, filter plus cable, at most 6.8 nF; no µF-class bulk capacitors; ripple filtered by series inductance. MUST Steep I-V curve P4; a current source gives fast arc detection and low arc energy P13; voltage sources with output capacitors are the classic arc problem [X5]X7

4.3 Ignition (IGN)

ID Requirement Level Basis
IGN-1 Open-circuit strike voltage programmable from 600 to 1200 V, goal 1500 V, current limited ("soft"). MUST / SHOULD MDX 500 1200 V range E2; MDX 1 kW 1500 V soft strike, 800 V low Z; MDX 1.5 kW 1200 V open circuit E3; Paschen behaviour P1
IGN-2 Holds the strike voltage into an open circuit without any fault. A configurable ignition timeout (default 5 s) ends the attempt with a "no ignition" status, not a latched error. MUST H1; E9
IGN-3 Ignition is recognised from current rise together with a voltage that settles above the arc threshold. A "plasma present" status is reported. The arc detector uses its own thresholds during the strike. MUST MDX reports "plasma is present" E2
IGN-4 After ignition the output ramps to the setpoint in a programmable time, 0.1 s to 10 min. MUST MDX 500: 0.1, 1 or 10 s; MDX 1 kW: 1 to 10 s or 1 to 10 min [E2]E3; new targets need gentle conditioning P8
IGN-5 The ignition transient does not trip any protection and does not overshoot the current limit by more than 50% for longer than 100 µs. MUST H1; E9
IGN-6 Digital output that can request a short gas pressure burst during the strike. MAY Our addition, follows from the Paschen curve P1

4.4 Regulation and metering (REG)

ID Requirement Level Basis
REG-1 Regulation modes: power (default), current, voltage, selectable at run time. MUST MDX and Pinnacle offer all three [E2][E3]E4
REG-2 The inner loop always regulates current. Power and voltage are outer loops. MUST Derived from the I-V steepness P4
REG-3 Setpoint accuracy 2% of reading or 0.5% of full scale, whichever is larger. Repeatability 1%. MUST MDX 500 display accuracy E2; TruPlasma 0.5% E5; Pinnacle 0.1% repeatability E4
REG-4 Readback of V, I and P at 1 kS/s or faster, plus arc count and arc rate. MUST Arc rate and count are process diagnostics P9
REG-5 Programmable limits for power, current, voltage and strike voltage, stored per machine profile in non-volatile memory. MUST Pinnacle: programmable output, strike and process limits, non-volatile settings E4
REG-6 Energy mode: stop after a set delivered energy in joules. SHOULD Pinnacle Joule mode E4
REG-7 Built-in I-V sweep that logs the curve and fits the exponent n. SHOULD n indicates confinement quality P4; 1/V follows the secondary electron yield of the target surface P7

4.5 Arc handling (ARC)

ID Requirement Level Basis
ARC-1 Arcs are quenched and the process resumes automatically. The supply never latches off on a first arc. MUST H1; Arc-Out E2; P8
ARC-2 Energy delivered into an arc after its onset: at most 5 mJ anywhere in the run envelope, goal 1 mJ at 500 V. Total output capacitance including cable at most 6.8 nF, goal 4.7 nF. MUST / SHOULD Stored-energy history P9; commercial figures [E4]E5; droplet size follows arc energy [P9]P10; budget in section 6.2
ARC-3 Detection by voltage collapse (absolute threshold 50 to 900 V, or relative 30 to 70% of the 1 ms average, default 50%), optionally combined with dV/dt and over-current. Detection time 2 µs or less. MUST Arc voltage is far below glow voltage, and the voltage criterion is the least ambiguous P8; Pinnacle 0.5 to 3 µs E4; TruPlasma adjustable U and I thresholds E5; voltage and dV/dt sensing X1
ARC-4 Gate drive inhibited, bridge switches off, within 2 us of arc detection, through a hardware path with no firmware in the loop. Energy delivered by the converter after inhibit is at most 1 mJ, measured with the arc simulator. The resulting C_out overshoot at restart stays within PRT-1. MUST About 10 µs was the state of the art in 2006 P8; Pinnacle 3000 interrupts for 10 µs E4
ARC-5 Off-time programmable from 100 µs to 100 ms, default 1 ms. Recovery by a controlled ramp, programmable 0.1 to 10 ms. If the plasma does not re-establish, the supply falls back to the strike state. MUST Programmable trip level, delay and shutdown time E4; shutdown of the order of milliseconds, longer off-times disturb the process more P9; hot spots must cool before power returns E2; the plasma needs time to re-establish P14
ARC-6 Progressive response: if the arc is still there at restart, the off-time is multiplied up to a limit, then a "hard arc" fault is latched. MUST Progressive arc shutdown X3; micro-arcs against hard arcs P9
ARC-7 Conditioning mode: the power limit is reduced automatically while the arc rate is above a threshold. SHOULD Target conditioning mode of Pinnacle Plus+ E4; oxide skin on new targets P8
ARC-8 Survives a continuous output short circuit and at least 10 000 arcs at full power without damage or drift. MUST MDX runs into any load mismatch and is protected against short and open circuits E3
ARC-9 Series inductance of the order of 1 mH between the output capacitor and the connector, so that arc current rises slowly and falls to zero by itself. SHOULD Less output inductance means higher peak current, longer arcs and more energy P12; ring-out and passive arc control [X2]X4
ARC-10 Mechanical and firmware provision for a later pulsed-DC stage: reverse voltage of 5 to 20% for 1 to 10 µs, at 10 to 250 kHz. MAY Pulsed DC removes charge from insulating layers [P1][P14][P15]X6

4.6 Protection (PRT)

ID Requirement Level Basis
PRT-1 Output over-voltage: hardware limit at 110% of the programmed strike voltage and an absolute hardware shutdown at 1.6 kV, both independent of firmware. MUST MDX: internal protection against over-voltage, over-current and over-power E3
PRT-2 Over-current and over-power: cycle-by-cycle limit on the primary side, firmware cap, absolute hardware cap. MUST E3; IN-3
PRT-3 Over-temperature sensing on switches, transformer and rectifiers: fold back first, then shut down. MUST S1 clause 10
PRT-4 Loss of the controller (watchdog, brown-out) disables the gate drive in hardware. MUST S1 single-fault condition
PRT-5 Plausibility checks on the sense chain (open divider, open shunt) lead to shutdown. MUST S1 single-fault condition
PRT-6 Every fault ends in the same safe state: converter off, output bled down, status latched and readable. MUST S1

4.7 Safety (SAF)

ID Requirement Level Basis
SAF-1 No hazardous-live part is accessible. Above 60 V DC a part counts as hazardous live (120 V DC under a single fault) unless current and charge are limited to 2 mA DC and 45 µC. This output exceeds those limits by orders of magnitude. MUST S1 clause 6.3
SAF-2 The output leaves the enclosure only through an SHV connector (5 kV, 5 A class, recessed contact, ground mates first) on solid-dielectric RG-59 coax. No banana jacks, no MHV. MUST E10; MHV not accepted for live connections E11; MDX offers SHV E2
SAF-3 Output below 60 V within 1 s after HV-off or loss of power, through a passive bleeder that needs no firmware. Design value about 0.1 s with 4.7 MΩ (derived). MUST 60 V within 5 s, 1 s for plug pins S2; hazardous-live limit S1
SAF-4 Stored charge at the highest voltage below 45 µC. With ARC-2 it is about 10 µC (derived). SHOULD S1 clause 6.3
SAF-5 Reinforced insulation between the HV secondary and everything else (24 V, control, interfaces), rated for 1.5 kV working voltage and verified by a voltage test. MUST S1 clauses 6.7 and 6.8; S3
SAF-6 PCB spacings at least those of IPC-2221B for 1.5 kV: 2.75 mm internal, 7.5 mm external uncoated, 3.85 mm external coated (derived). IPC gives functional spacing only: the HV to low-voltage barrier follows IEC 60664-1. MUST [S4]S3
SAF-7 Protective earth stud on the chassis, positive output bonded to the chassis, a dedicated terminal for an earth strap to the chamber baseplate. MUST S1 protective bonding; the MDX manual forbids defeating the ground connection E3
SAF-8 Hardware interlock loop of series contacts, fail-safe: at least vacuum OK, bell jar and HV shroud in place, cooling or over-temperature, emergency stop. Opening the loop removes the gate-drive enable. Restart needs a deliberate re-arm. MUST SEMI S2 sections 11 and 12 S5; SEMI S22 S6; MDX has vacuum, water and auxiliary interlock pins E2
SAF-9 "HV ON" indicator visible from the operator position, key or arming switch, hazard labels. MUST S1 clause 5; S5
SAF-10 No single component failure leaves the output energised with the interlock open. MUST S1 clause 4.4
SAF-11 Internal measurements only through built-in dividers and test points at safe levels. Cover removable only with a tool, with a discharge-time label. MUST S1

4.8 Interfaces (IF)

ID Requirement Level Basis
IF-1 Galvanically isolated digital interface (USB CDC and/or RS-485) with an open, documented protocol: on/off, mode, setpoints, limits, ramp, arc parameters, readback, status, faults. MUST Functions of the MDX user port E2; serial and fieldbus on larger units E4
IF-2 Status bits: interlock OK, output on, plasma present, at setpoint, ramping, arc occurred, fault. MUST MDX status list [E2]E3
IF-3 Analog programming and monitoring, 0 to 10 V, plus enable, as an optional board. MAY MDX 0 to 10 V E2
IF-4 Local controls: arming switch and HV indicator as a minimum, display optional. SHOULD E2
IF-5 Input for a temperature sensor on the magnetron body, with programmable power fold-back. SHOULD Magnets lost to overheating H1

4.9 EMC and robustness (EMC)

ID Requirement Level Basis
EMC-1 Design targets: emissions to CISPR 11 (EN 55011) Group 1 Class A, immunity to IEC 61326-1 industrial levels. SHOULD Pinnacle: IEC 61326-1; Pinnacle Plus+: EN 55011 and EN 61000-6-2 E4
EMC-2 The supply and its host link survive 10 000 arcs at full power without reset, lock-up or corrupted setpoints. MUST Arcs are sub-microsecond events with very fast current and voltage edges P8
EMC-3 Coaxial, shielded HV path from connector to feedthrough, with a single-point bond. MUST MDX output on RG-8 coax E2
EMC-4 The complete assembly (UHP plus supply plus cables) is re-checked for EMC. The UHP is a component supply whose compliance does not carry over to the final equipment. SHOULD E1

4.10 Environment and mechanics (ENV)

ID Requirement Level Basis
ENV-1 Indoor use, 5 to 40 °C, up to 2000 m, pollution degree 2. MUST Normal conditions of S1; MDX operates from 0 to 40 °C E2
ENV-2 Closed metal enclosure, finger-safe, no openings above HV parts. MUST S1 clause 6.2
ENV-3 Up to 18 W of loss removed by conduction to the enclosure, with a small fan as a fallback. SHOULD IN-4 (derived)

4.11 Replicability (REP)

ID Requirement Level Basis
REP-1 Every part orderable from mainstream distributors, with a second source for everything except the magnetics. MUST Same reasoning as the choice of the UHP-200-24: availability for everyone
REP-2 The HV transformer and the output inductor can be wound by hand on catalogue cores and bobbins, from a winding sheet with acceptance measurements (leakage inductance, winding capacitance, voltage test). MUST Proposed, follows from REP-1
REP-3 Schematic and PCB sources in an open format (KiCad proposed), firmware, bill of materials with sources and prices, and the test procedure are published. MUST Hacker Fab practice of publishing the BOM H1
REP-4 Assembly with an iron and hot air, no BGA parts. Board manufacturable at standard low-cost fabs. SHOULD Proposed, follows from REP-1
REP-5 A commissioning checklist that a builder without HV experience can follow, with clear stop points. MUST Section 5.2

5. Constraints

5.1 Design constraints

ID Constraint Why
C-1 One UHP-200-24 feeds the supply. Budget: at most 6 A of its 8.4 A, which leaves about 58 W for other 24 V loads of the machine. IN-1, IN-3 E1
C-2 Output power never exceeds 100 W. The cap exists twice, in hardware and in firmware. Section 2.3
C-3 DC only in v1: conductive targets, argon. Reactive sputtering of insulating oxides, RF and HiPIMS are out of scope. Steady DC on insulating layers arcs P14; RF is a later Hacker Fab goal H1
C-4 Low stored energy has priority over low ripple. No bulk capacitor on the output, ever, not even "temporarily for testing with plasma". ARC-2 [P9]X7
C-5 The arc, interlock and over-voltage shutdown paths are hardware. Firmware supervises, counts and decides on recovery, but is never the only thing between a fault and the gate drive. ARC-4, SAF-8 S5
C-6 Everything on the HV side is rated for 1.5 kV working voltage, with components derated to 2 kV or more. IGN-1, SAF-5
C-7 Parts and processes must stay within REP-1 to REP-4. A better part that cannot be bought by anyone is not an option. Availability goal

5.2 Electrical safety constraints

ID Constraint Why
C-8 The output is treated as lethal. At up to 0.4 A it is far outside what HV practice calls an output-limited supply (5 mA below 5 kV). Never connect or disconnect the HV cable with the supply armed. E11; S1 clause 6.3
C-9 Earthing is a star at the supply chassis: mains protective earth, UHP frame ground, chamber baseplate strap, coax shield. The positive output joins the chassis at one point, through the current shunt. OUT-1, SAF-7; all cathode current is then measured whatever its return path
C-10 The 24 V return is bonded to protective earth at one point. A floating 24 V bus could be lifted to cathode potential by a transformer insulation fault, and the UHP output is only tested to 1.25 kV AC against its frame. E1; S1
C-11 There is deliberately no ground-fault trip on the output. The protection against shock is enclosure, earthing, interlocks and discharge, not leakage detection. This is the opposite of the electrophoresis supply and must be stated in the manual. Section 1.2 H1
C-12 The cathode feedthrough on the air side of the baseplate is hazardous live. It needs an earthed or insulating shroud whose removal opens the interlock loop. S1 clause 6.3; the present feedthrough is a threaded rod through the baseplate H1
C-13 HV may only be armed below a pressure threshold and with the bell jar in place (vacuum interlock). SAF-8; MDX vacuum interlock pin E2

5.3 Machine and process constraints

ID Constraint Why
C-14 Default machine profile limits power to 20 W. Higher power is unlocked only for a source with validated cooling and a closed cooling interlock. Magnets overheat above about 20 W and have already been demagnetised once H1; all commercial sources of this size are water cooled [E6][E7]E8
C-15 Power density on the target stays below about 16 W/cm² with indirect cooling (113 W on 30 mm, 81 W on 1 inch). E7 (derived)
C-16 Gaps where no plasma is wanted (cathode body to ground shield) keep p*d well below 28 Pa cm at the highest operating pressure: under 7 mm at 300 mTorr, in practice a few millimetres. Paschen left branch P1 (derived)
C-17 HV cable no longer than 3 m, one piece, no splices. Typical RG-59 adds about 70 pF/m, which counts toward ARC-2. ARC-2; cable energy feeds the arc [X2]P20
C-18 New and oxidised targets, aluminium above all, are started in conditioning mode with a slow ramp. [P8]P22; ARC-7

6. Reference architecture (starting point, not binding)

6.1 Block diagram

mains -> [UHP-200-24] -> 24 V -> [fuse, filter, UVLO, input current limit]
      -> [resonant inverter, 100 to 300 kHz]
      -> [HV transformer, split secondaries]
      -> [rectifiers, series stacked]
      -> [C_out, a few nF] -> [L_out, about 1 to 2 mH]
      -> [bleeder + V divider] -> SHV -> RG-59 -> cathode (negative)

chamber baseplate (anode, positive) -> coax shield + earth strap -> chassis / PE
rectifier positive node -> [current shunt] -> chassis (single point)

[fast comparators: arc, over-voltage, over-current] -> [PWM inhibit, hardware]
[interlock loop] -> [gate-drive enable, hardware]
[MCU: state machine, loops, telemetry] <-> [isolated USB / RS-485]

Notes:

6.2 Arc energy budget (derived)

E_arc <= 1/2 * C_out * V^2  +  1/2 * L_out * I^2  +  P * t_resp
Case C_out at V L_out at I P * t_resp Total
Limit case: 6.8 nF, 1000 V, 0.1 A, 10 µs 3.4 mJ 0.01 mJ 1.0 mJ 4.4 mJ
Typical: 6.8 nF, 500 V, 0.2 A, 10 µs 0.85 mJ 0.04 mJ 1.0 mJ 1.9 mJ
Goal: 4.7 nF, 500 V, 0.2 A, 3 µs 0.59 mJ 0.04 mJ 0.3 mJ 0.9 mJ

7. Build plan

No fucking clue (low fucking clue to be precise), need to check with Alex and Tudor.

Verification matrix for step 8

Test Method Pass criterion
Output envelope Dummy loads at the corners, 30 min each OUT-2 to OUT-5, REG-3
Ripple Compensated HV probe at the connector, current probe in the return OUT-7
Efficiency and thermal Input and output power at 25, 50, 100 W; soak at 40 °C IN-4, ENV-3, PRT-3
UHP interaction Start-up, load steps, arc shutdown, short circuit, with the real UHP IN-3, IN-5, IN-6
Strike Open circuit hold, then a load switched in to emulate ignition IGN-1 to IGN-5
Arc energy Arc simulator at 250, 500, 800, 1000 V; integrate v*i ARC-2
Arc timing Scope: arc onset to comparator, to gate-off, to current zero ARC-3, ARC-4
Arc logic Single arcs, bursts, a persistent short ARC-1, ARC-5, ARC-6, ARC-7
Endurance 10 000 simulated arcs at 100 W, then repeat the accuracy test ARC-8, EMC-2
Faults Open divider, open shunt, controller reset, over-voltage injection, input brown-out PRT-1 to PRT-6
Discharge Scope on the output after HV-off and after pulling the 24 V SAF-3

8. Open questions for Hacker Fab

  1. Which power can the cooled source take, and when will it exist? Until then the 20 W profile of C-14 applies.
  2. Measured voltage and current today at 10, 50, 200 and 300 mTorr for Cu and Al (step 2). If the discharge sits below 250 V at high pressure, OUT-3 has to move.
  3. Target pressure range after the turbopump, and whether a gas burst for ignition is acceptable.
  4. Target materials planned beyond Cu and Al. Magnetic targets and intentional oxides change the requirements.
  5. Geometry: cathode to shield gap, cathode to baseplate distance, feedthrough voltage rating, and who builds the HV shroud of C-12.
  6. Which controller talks to the supply, and over which interface (USB, RS-485, analog).
  7. Which interlock signals exist or can be added: vacuum gauge relay, bell jar switch, coolant flow, emergency stop.
  8. Cable length between supply and chamber.
  9. Cost ceiling for the bill of materials, excluding the UHP.
  10. Is the pulsed-DC option (ARC-10) wanted soon enough to reserve board space for it in rev A?

9. References

Hacker Fab

Papers and conference material

Further reading, not used for specific numbers: J. T. Gudmundsson, "Physics and technology of magnetron sputtering discharges", Plasma Sources Sci. Technol. 29, 113001 (2020), https://doi.org/10.1088/1361-6595/abb7bd; P. J. Kelly, R. D. Arnell, "Magnetron sputtering: a review of recent developments and applications", Vacuum 56, 159-172 (2000); R. Scholl, "Power Supplies for Pulsed Plasma Technologies: State-of-the-Art and Outlook", Advanced Energy white paper.

Equipment datasheets

Patents

Standards